Contact an OEM Specialist             
logo                                                                   

dpss

ce     ul     rohs     iso 

BTC112 TE Cooled 16-bit USB Linear CCD Array Spectrometer

The BTC112 series is a low cost, high performance, Thermoelectric Cooled (TEC) linear CCD array spectrometer solution. Equipped with 2048 elements, built-in 16-bit digitizer, and high-speed USB 2.0 interface, this TE Cooled spectrometer will continuously deliver optimized high throughput results. Compared to non-cooled CCD spectrometers, the BTC112 offers higher dynamic range, significantly reduced dark counts, and superior long-term operation stability, making it ideal for low light level detection and long-term monitoring applications. Wavelength configurations are available from as low as 200nm to as high as 1050nm with resolutions between 0.6nm and 4.0nm with standard configurations. Flexible custom configurations and application support are available for OEM applications.

Features:
• UV - NIR Range                    • 0.6nm - 4.0nm Resolution Range
• TE Cooled / Regulated           • 16-bit Digitizer
• 500 kHz Readout Speed        • Plug-and-play USB 2.0

Click Here for the End User Version of this Product

Contact an OEM Specialist for more Information

Customized Resolution and Wavelength Coverage from 200-1050nm


DC Power Input

5V DC < 1.5 Amps

AC Adapter Input

100 - 240VAC 50/60 Hz, 0.5A @ 120VAC

Detector Type

Response Enhanced 2048 element linear silicon CCD array

Pixels

2048 x 1 elements @ 14μm x 200μm per element

Spectrograph F#

3.2

Spectrograph Optical Layout

Crossed Czerny-Turner

Dynamic Range

300 typical

Digitizer Resolution

16-bit or 65,535:1

Readout Speed

500 kHz

Data Transfer Speed

Up to 180 spectra per second via USB 2.0

Integration Time

5 ~ 65,535ms x multiplier

External Trigger

Aux Port

Operating Temperature

15°C - 35°C

Operational Relative Humidity

85% Noncondensing

TE Cooling

14°C

Weight

0.60 kg (1.32 lbs)

Dimensions

127.0mm x 39.0mm x 90.7mm (5in x 1.5in x 3.6in)

Computer Interface

USB 2.0 / 1.1

Operating Systems

Windows: XP, Vista (32-bit), 7 (32-bit)




Specifications Wavelength

200nm -1050nm
Accuracy 1 pixel

Stray Light Rejection

 0.05% at 600nm
< 0.10% at 435nm

Dynamic Range

300:1 Typical 

Digitizer Resolution

16-bit or 65,535:1

Digitizer Speed

500 kHz

Integration Time

5 ~ 65,535ms x multiplier
Multiplier 1-16

Ambient Operating Temperature

15°C to 35°C

Optical Design

Crossed Czerny-Turner
F# 3.2

Entrance Aperture

Default SMA905
Custom Available

Focal Length

Input 37.5mm
Output 42.5mm

Grating Options

Contact us

Order Sorting Filter

LVF
High Pass
Low Pass

Slit Options

10µm
25µm - Standard
50µm
100µm
Custom

Optical Resolution

0.6nm to 4.0nm

Collection Lens

Optional Cylindrical Lens

Detector

Sony ILX511
TE Cooled
UV Response enhanced linear Silicon CCD Array

Detector Range

190nm -1100nm

Pixel Number

2048

Pixel Size

14µm x 200µm

Detector Length

28.7mm

Well Depth

~90,000 Electrons

TE Cooling

1 Stage
Temperature Setting 14ºC
Temperature Control N/A


Data Acquisition

USB 2.0/1.1

Trigger Mode

5V TTL I/O

Power Input

5V DC < 1.5 Amps

Warm Up Time

< 30 minutes

Physical Specification

Length: 127mm
Width:  90.7mm
Height:  39mm
Weight: 0.60kg

Spectrometer Software Available

BWSpec™
SDK Program

OS Compatibility

Windows XP
Windows Vista(32-bit)
Windows 7 (32-bit)

Minimum Hardware Requirements

800MHz P4
512 RAM
1 Gigabyte available Hard Drive space

 


1127mm x 39mm x 90.7mm (5in x 1.5in x 3.6in) :

Dimensional Drawing



      © 2010 B&W Tek, Inc. All rights reserved. - Specifications are subject to change without notice.