Contact an OEM Specialist             
logo                                                                   

dpss

ce     ul     rohs     iso 

BTC661 Fiber Coupled Back-thinned USB 2.0 CCD Array Spectrometer

The BTC661 series are high performance TE Cooled back-thinned CCD array spectrometers. They are equipped with a high sensitivity 2048 x 112 CCD array, optimized high throughput spectrographs, fiber coupled input capability, built-in 16-bit digitizer, and high speed USB 2.0 interface. Using a proprietary optical design high dynamic range, high signal-to-noise ratio, low dark counts, and long-term operation stability are achieved. Further more, they are ideal for light starving applications from UV to NIR. Flexible custom configurations and custom application support are provided.

Features:
• Over 60% QE Down at 200 nm           • Over 90% Peak QE
• High UV, Vis, and NIR Response        • Line and Pixel Binning for Superior S/N Enhancement
• TE Cooled 2048 Elements                  • Shutter Standard

This Detector, End User Version Available

Contact an OEM Specialist for more Information

Custom Wavelengths Available for 532nm or 785nm Raman Spectrometers


Power Input

100-240 VAC, 50/60 Hz

Detector Type

Response Enhanced 2048 element Back-thinned linear silicon CCD array

Active Pixels

2048 x 122 / 24.576 x 1.1464mm

Spectrograph F#

2.2 (standard) : 2.8 (high resolution)

Spectrograph Optical Layout

Transmission / Reflection

Dynamic Range

~3.0 x 104

Digitizer Resolution

16-bit or 65,535:1

Readout Speed

250 kHz

Integration Time

9ms to 16 minutes (Linear Mode); 2 hours (2D Mode)

External Trigger

Aux Port

Operating Temperature

5°C to 30°C

TE Cooling

1-Stage -10°C; 2-Stage -20°C

Weight

Spectrometer: 1.8 kg (3.9 lbs), Power Supply: 0.9 kg (1.9 lbs)

Dimensions

Spectrometer: 260 x 125 x 90mm (10.2 x 4.9 x 3.5in)
Power Supply: 249 x 169 x 57mm (9.8 x 6.6 x 2.2in)

Computer Interface

USB 2.0

Operating Systems

Windows XP, Vista (32-bit)




Specifications Wavelength

Optimized for 532nm Raman
Optimized for 785nm Raman
Accuracy 1 pixel

Stray Light Rejection

0.07% at 800nm

Dynamic Range

30,000:1 Minimum

Digitizer Resolution

16-bit

Digitizer Speed

250kHz

Integration Time

9ms - 65,535ms
Multiplier 1 - 16

Ambient Operating Temperature

15°C to 35°C

Optical Design

Double Pass Transmission
F# 2.8/2.2

Entrance Aperture

Default SMA905
Custom Available

Focal Length

Input 72mm
Output 72mm

Grating Options

Contact us

Order Sorting Filter

High Pass

Slit Options

20µm
10µm

Optical Resolution

> 0.3nm

Collection Lens

NA

Detector

Hamamatsu S10141-1107S
TE Cooled
Back-thinned 2D-vertically binned

Detector Range

Optimized for 532nm Raman
Optimized for 785nm Raman

Pixel Number

2048

Pixel Size

12µm x 1464µm

Detector Length

24.6mm

Well Depth

200,000 Electrons

TE Cooling

1 Stage
Factory Default 0°C
Range -20°C to 0°C
Temperature Control N/A


Data Acquisition

USB 2.0/1.1

Trigger Mode

5V TTL I/O

Power Input

110-240 VAC, 50/60Hz

Warm Up Time

< 30 minutes

Physical Specification

Spectrometer:
Length:  260mm
Width:   125mm
Height:     90mm
Weight:   1.8kg

Power Supply:
Length:  249mm
Width:    169mm
Height:    57mm
Weight:   0.9kg

Spectrometer Software Available

BWSpec™
SDK Program

OS Compatibility

Windows XP
Windows Vista

Minimum Hardware Requirements

800MHz P4
512 RAM
1 Gigabyte available Hard Drive space

 


260 x 125 x 90mm (10.2 x 4.9 x 3.5in) :

Dimensional Drawing



      © 2010 B&W Tek, Inc. All rights reserved. - Specifications are subject to change without notice.